Estairs logo      
   
Email: mail@estairs.co.uk | Tel: 0844 884 3214 | Mobile: 07980 523 498
  Estairs HomeGenius HomeArke Home PaymentsTech helpContact Us  
Technical Drawings

Click on the links below to download technical drawings for each staircase kit.

pdf   Civik Spiral Stairs
pdf   Klan Wooden Tread Spiral
pdf   Karina Utility Space Saving Staircase
pdf   Kompact 74 & 89
pdf   Kompact 89 BS
Assembly Instructions

Click on the links below to download the assembly instructions for each staircase kit.

pdf   Civik Spiral
pdf   Civik Zink Outdoor Spiral
pdf   Klan Wooden Tread Spiral
pdf   Karina Utility Space Saving Staircase
pdf   Kompact Designer Custom
Adobe reader logo Adobe Acrobat Reader is required to view these files. If you don’t already have the programme installed on your PC you may download it free of charge from Adobe by clicking on the icon:
Building Regulations

Arke Staircases are used on a wide variety of projects and applications but British building regulations are complex and it is your responsibility to ensure that your chosen stair is compliant. As a broad rule of thumb the following is a guide only and must be verified by your local building inspector.

For General Storage Areas, mezzanines and areas requiring access for maintenance such as a loft or cellar, all models may be suitable.

BUILDING REGULATIONS BS 5395
British Standard – Stairs, Ladders & Walkway

“Where stair serves only sanitary accommodation and/or one room…”
ARKE SPIRALS
  • 120mm Dia: NON COMPLIANT.
  • 140mm Dia: Complies with one exception, the minimum clear width is 566.5mm for the Klan and 585mm for the Civik. The recommendation is 600mm. Check with Building Inspector, most will allow.
  • 160 & 150mm Dia: Complies.
OTHER ARKE MODELS
  • Kompact 74, 89 & 89BS: Complies.
  • Karina (Space Saver): NON COMPLIANT unless there is no room for normal stair.


“The width of a private stair may be reduced to at least 800mm…”
  • ARKE Kompact 89BS is the only model to Comply.
N.B. – For all of the above to comply:-
  • Riser Bar Kit must be fitted.
  • Max Gap from wall (Kompact & Karina): Less than 50mm. If greater, an additional handrail (kit external railing) will be required.
  • Max Rise: 220mm.
  • Maximum of 16 rises allowed in any one flight. If a greater number of rises are required, a landing should be introduced at some point.
For a full copy of UK Building Regulations relating to stairs click here.